General

The Configuration section of a monitoring project closely resembles basic project configuration, with a few settings specific to monitoring projects. The following read-only settings are displayed for informational purposes and can only be modified by XTC administrators:

  • Data Persistence (how long data like execution history persists in storage), and
  • Execution Environment (IP addresses of agent machines running monitoring scenarios).

Dynamic repository branch

In the repository configuration, you can specify a static branch name or define a resource URL. From this URL, XTC extracts the branch name dynamically using a regular expression. This approach helps tie scenario execution directly to the application version currently deployed.

Scenario defaults

On the Scenario Defaults tab in Configuration, you can define default settings for all monitoring scenarios, including the default Reply-To address and alert notification toggles. You can override these defaults for each individual scenario. To edit scenario defaults, click the edit button on the right of any section:

The scenario defaults tab with expand toggle and editing button. The scenario defaults tab with expand toggle and editing button.

Notification lists

XTC provides fine-grained control over when alerts trigger and who receives them. Instead of relying on a single recipient list, you define dedicated notification lists and link them to specific trigger conditions using quality sensors.

Notification lists are configured on the Notifications tab of the project configuration.

In a typical project, notification lists map to operational responsibilities:

  • On-Call Team: evaluates scenario failures and initiates operational responses.
  • Monitoring Dev Team: maintains scenario scripts and resolves test failures.
  • App Dev Team: investigates application performance issues and regressions.

Configure the default Reply-To Address for notification emails on the Scenario Defaults tab. If left blank, this defaults to a no-reply address. Set a dedicated team inbox to receive replies.

Defining a notification list

To add a notification list, navigate to the Notifications tab in Configuration and click New. Enter a name and optional description for the list.

The new notification list appears in the overview table.

Notification lists overview table. Notification lists overview table.

Use the context menu to edit the name and description, duplicate the list, or delete it after confirmation. You can also pause or disable notifications for a single list.

To view subscribers and verify assignments, click the list name or select View from the context menu.

Notification list detail view. Notification list detail view.

To add subscribers, open the Subscribers tab in the list detail view and click Add. You can add XTC user subscribers (existing accounts with stored contact data) or custom subscribers (custom email address, phone number, or push topic). Supported channels include email, push notifications (via ntfy.sh), and Slack channels. You can update subscriber details at any time, or deactivate and remove subscribers.

Push notifications setup

To receive instant monitoring alerts on a mobile device:

  1. Install the ntfy app on your mobile device (available for iOS and Android).
  2. Open your account settings and navigate to Profile > Push Notifications.
  3. Generate a unique notification topic and scan the QR code with your mobile device. The ntfy app subscribes to your topic automatically.
  4. Click Send Test Message in XTC to verify that notifications arrive.
  5. In your project’s Notification List, edit a user or custom subscriber and enable the Push Notification channel.

Notification list assignments

After configuring a notification list, assign it to quality sensors. The Assignments tab in the list details page displays every quality sensor referencing the list. Review this tab before modifying a list to see which scenario alerts change.

Activation times

By default, monitoring alerts dispatch around the clock on every calendar day. While appropriate for critical functional outages, you can restrict minor alerts to business hours.

Activation times define recurring time windows during which notifications reach subscribers. For instance, notifications can run Monday through Friday from 9 AM to 5 PM. You can add up to 20 activation times per notification list. Outside these windows, XTC suppresses notifications.

A newly created activation list is active around the clock by default.

To restrict active hours, open the notification list, and select the Activation Times tab. Edit the default entry or create new time windows with the following properties:

  • Name and description.
  • Active weekdays.
  • Start time.
  • End time (including 59 seconds, such that 23:59 extends to 23:59:59).
  • Target time zone for the schedule.

You can configure several activation times for different days. Overlapping time windows function normally. Notifications dispatch whenever at least one window is active.

Pausing or disabling notifications

On the project configuration Notifications tab, you can enable or disable notifications globally for the entire project.

To pause notifications and optionally suspend scenario runs for a scheduled window, configure quiet periods.

To toggle alerts for an individual list, use the list context menu in the notification lists table. An icon in the table indicates the current notification state.

Notification lists that do not receive notifications. Notification lists that do not receive notifications.

Quality sensors

A quality sensor defines when XTC triggers an alert and which notification lists receive it. Because these criteria apply across scenarios, you configure sensors at the project level and assign them to test scenarios as needed. You can configure multiple quality sensors in a project, and assign several sensors to a single scenario.

Defining a quality sensor

To add a quality sensor, navigate to the Quality Sensors tab in Configuration and click New. Specify a name, description, and failure threshold based on consecutive executions (for example: 1/1 alerts on every failure; 3/3 alerts when a scenario fails 3 consecutive times; 3/10 alerts when 3 of the last 10 executions fail).

Adding a new quality sensor to the project. Adding a new quality sensor to the project.

Quality sensors overview. Quality sensors overview.

The quality sensor appears in the overview table. Use the context menu to edit settings, duplicate the sensor, or delete it after confirmation. To configure metrics and notification lists, click the sensor name or select View from the context menu.

Quality sensor detail view. Quality sensor detail view.

Adding metrics to a quality sensor

On the Configuration tab of the quality sensor detail view, define metrics: conditions that must all pass for the scenario run to succeed.

To add metrics, open the Configuration tab and click Add in the Metrics section. Select criteria from the following categories:

  • General: checks for execution errors and scenario failures.
  • Event: checks timing for page load events (DomContentLoaded, First Contentful Paint, First Paint, Load Event).
  • Web Vitals: checks Core Web Vitals criteria (Cumulative Layout Shift, First Contentful Paint, First Input Delay, Interaction to Next Paint, Largest Contentful Paint, Time to First Byte).
  • XLT: checks runtime limits for transactions, actions, or requests, as well as request errors.

Depending on the metric, configure the threshold as an occurrence check, a duration in milliseconds, or a specific metric parameter. You can edit or delete defined metrics using their context menu.

When a scenario violates a metric threshold across the configured consecutive runs, XTC triggers an alert and notifies the assigned notification lists.

Managing notification lists of a quality sensor

The notification lists assigned to a quality sensor define who receives an alert when the sensor fails.

To assign a configured notification list to the quality sensor, open the Configuration tab and click Add in the Notification Lists section. Select the target notification list from the dialog.

To detach a notification list, click Remove in its context menu on the Configuration tab. This stops alerts for this sensor without deleting the underlying list. To delete a list entirely, manage it on the project Notifications tab.

Quality sensor assignments

After configuring quality sensors, assign them to your scenarios. The Assignments tab in the sensor details page displays every scenario using the sensor. Check this tab before updating a sensor to verify which scenario runs change.

In a typical project, quality sensors follow a three-tier structure:

  • Preparation: verifies that the scenario environment is ready and notifies the Monitoring Dev Team list on fatal errors. Blocks execution of later sensors on failure (such as Git download errors or compile issues).
  • Stability: verifies that the scenario runs without scenario errors. Notifies the On-Call Team and Monitoring Dev Team lists, and blocks execution of later sensors on failure.
  • Performance: verifies that response times and Web Vitals stay within specified limits. Notifies the App Dev Team when metrics exceed thresholds.

Assign these quality sensors to each scenario in this sequence.

If a scenario requires unique alert thresholds, define a dedicated quality sensor or notification list.

Last updated on